Garlic bread samples each weighing 170g
contained 35g of garlic butter. The butter had
a concentration of garlic (either control fresh
cloves or Dr Sakai garlic) at a concentration
of 21%. All samples were held in a refrigerator
at 4ºC until used. The bread was baked for
12 minutes at an oven temperature of 180ºC
immediately prior to consumption.
Pre-Concentration of Breath Samples
for GC-MS Analysis
Two non smoking male subjects, each
weighing approximately 8Okg consumed one garlic
baguette containing the control garlic at approximately
11am after refraining from any garlic products
for the previous 24 hours (but with no other modifications
to the normal diet). Before consumption of the
garlic bread a breath sample was taken and used
as a blank. A breath sample was taken directly
after the consumption of the garlic bread (0 hours),
then at 3 hours and 5 hours after consumption.
A 3.4mm ID Unpacked glass injector insert was
tightly packed with 75mg of Tenax TA, with a plug
of glass wool at either end. The weight of packing
was determined by weighing the pre column before
and after packing. The subject held a Teflon tube
in the oral cavity, and whilst inhaling through
the nose and exhaling via the mouth, 100 ml of
breath was drawn slowly through the pre concentration
tube. The pre concentration tube was instantly
detached from the Teflon tubing and placed into
the GC/MS injection port and thermally desorbed
at 250ºC. Prior to re-use the trap was baked
at 2500C for 30 minutes. Blank runs of the reconditioned
trap proved that there was no carryover between
samples.
The same experiment, with the same controls
(cross-over design) was repeated several days
later to avoid
any carry-over, using garlic baguettes containing
Dr Sakai garlic instead of the control.
Direct Sampling for P-FPD The
P-FPD detector did not require a pre-concentration
stage. An aliquot of breath
was withdrawn from the subject’s mouth via
Teflon tube in the oral cavity. A direct injection
of
0.5 ml was then introduced into the system.
As with the pre concentration method a blank
breath
sample was taken immediately prior to consumption
of the garlic bread. Immediately after consumption
of the garlic bread the first sample was taken
(0 hours) with subsequent samples taken every
15 minutes up to and including 60 minutes.
This analysis was only preformed on the control
garlic
bread by subject one.
GC/MS
Operating Parameters The
GC/MS was a Saturn 4D ion trap mass spectrometer
supplied by Varian (Varian Associates Inc. CA)
with Varian Star 3400 CX GC.
Column:
30 M x 0.25 mm
i.d. x 0.25 μm film thickness DB5-MS
(J&W Scientific)
Carrier:
Helium 30 ml/min
Column Oven: (Cooled with liquid CO2 )
-10°C for 3 min, 10°C/min
to 300°C
Injector:
50°C for 0.5 min; 300°C/min
to 250°C, hold for run.
Transfer Line:
260°C
Injector Mode:
Splitless injection for first
5 min of run
Mass Range:
45 - 100
Scan Time:
1 sec
Mult. Delay:
0.1 min
Peak Threshold:
1 count
Ion Mode:
Electron Impact
Ion Trap:
260°C
Table 1: Instrumental Conditions for Mass
Spectrometer
Compounds were tentatively identified
by comparison to reference spectra via the mass
spectral database. Compounds tentatively identified
were confirmed by comparing their mass spectra
and GC retention times to those of authentic compounds
analysed in the laboratory under identical conditions.
Quantitation was performed using the Q ion for
methyl mercaptan (m\z 47) and peak area for all
other compounds.